MSS60 Error: 2724, P0132

From Wiki-DIY
Jump to: navigation, search

2724 - P0132

Information saved in DME
Fault code 2724 - P0132
Fault text Oxygen sensor, signal before cat., bank 1
Fault description O2 Sensor Circuit High Voltage (Bank 1 Sensor 1)
Condition for fault identification Test condition: lavk_atic42_pin_diag_b1 BIT1 or BIT3 or BIT5 or BIT7 set
Terminal condition: none
Voltage condition: none
Condition for fault memory entry 3000 ms
Action in service 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B1,
2. If OK replace oxygen sensor
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction None