MSS60 Error: 2B64, P0073

From Wiki-DIY
Revision as of 14:24, 3 February 2015 by Rcollins (talk | contribs) (Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2B64 - P0073 |- |'''Fault text''' |Ambient-temperature sensor |- |'''Fault description''' |Ambient Air Tempera...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search
Information saved in DME
Fault code 2B64 - P0073
Fault text Ambient-temperature sensor
Fault description Ambient Air Temperature Sensor Circuit 'A' High
Condition for fault identification Test condition: Error message from CAN I-cluster message
Terminal condition: B_ZUST_ML && B_EMPF_ATEMP
Voltage condition: none
Condition for fault memory entry 10000 ms
Action in service 1. Check plug and wiring harness.
2. Check stored error codes logged in I-cluster.
3. Replace ambient temperature sensor.
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction none