Difference between revisions of "MSS60 Error: 2B64, P0073"

From Wiki-DIY
Jump to: navigation, search
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2B64 - P0073 |- |'''Fault text''' |Ambient-temperature sensor |- |'''Fault description''' |Ambient Air Tempera...")
 
 
Line 1: Line 1:
{|
+
__FORCETOC__
|
+
 
|
+
 
 +
==== '''2B64 - P0073''' ====
 +
{| class = "diyTable ecuFault"
 
|-
 
|-
 
|'''Information saved in'''
 
|'''Information saved in'''

Latest revision as of 14:24, 3 February 2015


Contents

2B64 - P0073

Information saved in DME
Fault code 2B64 - P0073
Fault text Ambient-temperature sensor
Fault description Ambient Air Temperature Sensor Circuit 'A' High
Condition for fault identification Test condition: Error message from CAN I-cluster message
Terminal condition: B_ZUST_ML && B_EMPF_ATEMP
Voltage condition: none
Condition for fault memory entry 10000 ms
Action in service 1. Check plug and wiring harness.
2. Check stored error codes logged in I-cluster.
3. Replace ambient temperature sensor.
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction none