Information saved in
|
DME
|
Fault code
|
2B29 - P16B1
|
Fault text
|
Moment manager monitoring
|
Fault description
|
Control Module Self-Test, Idle Air Control System Integrated Component Plausibility
|
Condition for fault identification
|
Test condition: I-component greater than 70 Nm (K_MD_SK_LLR_MAX)
|
|
Terminal condition: Terminal 15
|
|
Voltage condition: None
|
Condition for fault memory entry
|
10 ms
|
Action in service
|
1. Clear fault memory
|
|
2. Update DME
|
|
3. Replace DME
|
Fault effect and breakdown warning
|
CC message
|
|
Engine speed limited
|
|
Reduced power
|
|
MIL after engine runs 2x
|
Driver information
|
Warning light: MIL, EML, CC message, backup program
|
Service instruction
|
None
|
Information saved in
|
DME
|
Fault code
|
2B29 - P16B7
|
Fault text
|
Moment manager monitoring
|
Fault description
|
Control Module Self-Test, Clutch Torque Monitoring Maximum Value Plausibility
|
Condition for fault identification
|
Test condition: Specified torques greater than 620 Nm (K_MD_SK_IND_MAX)
|
|
Terminal condition: Terminal 15
|
|
Voltage condition: None
|
Condition for fault memory entry
|
10 ms
|
Action in service
|
1. Clear fault memory
|
|
2. Update DME
|
|
3. Replace DME
|
Fault effect and breakdown warning
|
CC message
|
|
Engine speed limited
|
|
Reduced power
|
|
MIL after engine runs 2x
|
Driver information
|
Warning light: MIL, EML, CC message, backup program
|
Service instruction
|
None
|
Information saved in
|
DME
|
Fault code
|
2B29 - P16B8
|
Fault text
|
Moment manager monitoring
|
Fault description
|
Control Module Self-Test, Clutch Torque Monitoring Minimum Value Plausibility
|
Condition for fault identification
|
Test condition: Minimum torque greater than 70 Nm (K_MD_SK_MAX_MDMIN)
|
|
Terminal condition: Terminal 15
|
|
Voltage condition: None
|
Condition for fault memory entry
|
10 ms
|
Action in service
|
1. Clear fault memory
|
|
2. Update DME
|
|
3. Replace DME
|
Fault effect and breakdown warning
|
CC message
|
|
Engine speed limited
|
|
Reduced power
|
|
MIL after engine runs 2x
|
Driver information
|
Warning light: MIL, EML, CC message, backup program
|
Service instruction
|
None
|
Information saved in
|
DME
|
Fault code
|
2B29 - P16C1
|
Fault text
|
Moment manager monitoring
|
Fault description
|
Control Module Self-Test, Torque Monitoring Current Indicated Value Plausibility
|
Condition for fault identification
|
Test condition: Difference too large
|
|
Terminal condition: Terminal 15
|
|
Voltage condition: None
|
Condition for fault memory entry
|
10 ms
|
Action in service
|
1. Check load monitoring
|
|
2. Clear fault memory
|
|
3. Update DME
|
|
4. Replace DME
|
Fault effect and breakdown warning
|
CC message
|
|
Engine speed limited
|
|
Reduced power
|
|
MIL after engine runs 2x
|
Driver information
|
Warning light: MIL, EML, CC message, backup program
|
Service instruction
|
None
|