Difference between revisions of "MSS60 Error: 2B29, P16B1, P16B7, P16B8, P16C1"

From Wiki-DIY
Jump to: navigation, search
(Created page with "<nowiki>__FORCETOC__</nowiki> {| |'''Information saved in''' |DME |- |'''Fault code''' |2B29 - P16B1 |- |'''Fault text''' |Moment manager monitoring |- |'''Fault description'...")
 
 
Line 1: Line 1:
<nowiki>__FORCETOC__</nowiki>
+
__FORCETOC__
  
{|
+
====2B29 - P16B1====
 +
 
 +
{| class = "diyTable ecuFault"
 +
|-
 
|'''Information saved in'''
 
|'''Information saved in'''
 
|DME
 
|DME
Line 53: Line 56:
 
|None
 
|None
 
|}
 
|}
{|
+
 
 +
 
 +
====2B29 - P16B7====
 +
 
 +
{| class = "diyTable ecuFault"
 +
|-
 
|'''Information saved in'''
 
|'''Information saved in'''
 
|DME
 
|DME
Line 105: Line 113:
 
|None
 
|None
 
|}
 
|}
{|
+
 
 +
 
 +
====2B29 - P16B8====
 +
 
 +
{| class = "diyTable ecuFault"
 +
|-
 
|'''Information saved in'''
 
|'''Information saved in'''
 
|DME
 
|DME
Line 157: Line 170:
 
|None
 
|None
 
|}
 
|}
{|
+
 
 +
 
 +
====2B29 - P16C1====
 +
 
 +
{| class = "diyTable ecuFault"
 +
|-
 
|'''Information saved in'''
 
|'''Information saved in'''
 
|DME
 
|DME

Latest revision as of 21:51, 4 February 2015


2B29 - P16B1

Information saved in DME
Fault code 2B29 - P16B1
Fault text Moment manager monitoring
Fault description Control Module Self-Test, Idle Air Control System Integrated Component Plausibility
Condition for fault identification Test condition: I-component greater than 70 Nm (K_MD_SK_LLR_MAX)
Terminal condition: Terminal 15
Voltage condition: None
Condition for fault memory entry 10 ms
Action in service 1. Clear fault memory
2. Update DME
3. Replace DME
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None


2B29 - P16B7

Information saved in DME
Fault code 2B29 - P16B7
Fault text Moment manager monitoring
Fault description Control Module Self-Test, Clutch Torque Monitoring Maximum Value Plausibility
Condition for fault identification Test condition: Specified torques greater than 620 Nm (K_MD_SK_IND_MAX)
Terminal condition: Terminal 15
Voltage condition: None
Condition for fault memory entry 10 ms
Action in service 1. Clear fault memory
2. Update DME
3. Replace DME
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None


2B29 - P16B8

Information saved in DME
Fault code 2B29 - P16B8
Fault text Moment manager monitoring
Fault description Control Module Self-Test, Clutch Torque Monitoring Minimum Value Plausibility
Condition for fault identification Test condition: Minimum torque greater than 70 Nm (K_MD_SK_MAX_MDMIN)
Terminal condition: Terminal 15
Voltage condition: None
Condition for fault memory entry 10 ms
Action in service 1. Clear fault memory
2. Update DME
3. Replace DME
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None


2B29 - P16C1

Information saved in DME
Fault code 2B29 - P16C1
Fault text Moment manager monitoring
Fault description Control Module Self-Test, Torque Monitoring Current Indicated Value Plausibility
Condition for fault identification Test condition: Difference too large
Terminal condition: Terminal 15
Voltage condition: None
Condition for fault memory entry 10 ms
Action in service 1. Check load monitoring
2. Clear fault memory
3. Update DME
4. Replace DME
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None