Difference between revisions of "MSS60 Error: 2B25, P154C, P154D, P154E, P154F"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2B25 - P154C |- |'''Fault text''' |Throttle-valve monitoring, bank 1 |- |'''Fault description''' |Throttle Act...") (Tag: Visual edit) |
|||
Line 1: | Line 1: | ||
− | + | __FORCETOC__ | |
− | + | ||
− | | | + | |
+ | ==== '''2B25 - P154C''' ==== | ||
+ | {| class = "diyTable ecuFault" | ||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 56: | Line 58: | ||
− | + | ==== '''2B25 - P154D''' ==== | |
− | + | {| class = "diyTable ecuFault" | |
− | |||
− | {| | ||
− | |||
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 116: | Line 114: | ||
− | + | ==== '''2B25 - P154E''' ==== | |
− | + | {| class = "diyTable ecuFault" | |
− | |||
− | {| | ||
− | |||
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 182: | Line 176: | ||
− | + | ==== '''2B25 - P154F''' ==== | |
− | + | {| class = "diyTable ecuFault" | |
− | |||
− | {| | ||
− | |||
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' |
Latest revision as of 14:10, 3 February 2015
2B25 - P154C
Information saved in | DME |
Fault code | 2B25 - P154C |
Fault text | Throttle-valve monitoring, bank 1 |
Fault description | Throttle Actuator Monitoring Dissimilar Desired Values (Bank 1) |
Condition for fault identification | Test condition: Difference too large |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min) | |
Condition for fault memory entry | 300 ms |
Action in service | 1. Clear fault memory, EDR system test |
2. Check plug, wiring harness and power supply to EDR1 | |
3. Replace EDR1 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B25 - P154D
Information saved in | DME |
Fault code | 2B25 - P154D |
Fault text | Throttle-valve monitoring, bank 1 |
Fault description | Throttle Actuator Monitoring Incorrect Actual Value (Bank 1) |
Condition for fault identification | Test condition: Difference too large |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min) | |
Condition for fault memory entry | 300 ms |
Action in service | 1. Clear fault memory, EDR electronic throttle valve control system test, |
2. Check 2nd plug, wiring harness and power supply for throttle valve DK1, EDR1 and DME, | |
3. Replace DK1 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B25 - P154E
Information saved in | DME |
Fault code | 2B25 - P154E |
Fault text | Throttle-valve monitoring, bank 1 |
Fault description | Throttle Actuator Monitoring Actual Value / Desired Value Correlation (Bank 1) |
Condition for fault identification | Test condition: Difference too large |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min) | |
Condition for fault memory entry | 350 ms |
Action in service | 1. Clear fault memory, EDR electronic throttle valve control system test, |
2. Check plug, wiring harness and power supply to throttle valve DK1 and EDR1 | |
3. Check throttle valve assembly B1 for mechanical stiction | |
4. Replace DK1 | |
5. Replace EDR1 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B25 - P154F
Information saved in | DME |
Fault code | 2B25 - P154F |
Fault text | Throttle-valve monitoring, bank 1 |
Fault description | Throttle Actuator Monitoring Reset Error (Bank 1) |
Condition for fault identification | Test condition: Not identical for too long |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min) | |
Condition for fault memory entry | 250 ms |
Action in service | 1. Clear fault memory, EDR system test |
2. Check plug, wiring harness and power supply to EDR1 | |
3. Replace EDR1 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |