Difference between revisions of "MSS60 Error: 2B16, P0639, P1630, P210A"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2B16 - P1630 |- |'''Fault text''' |Throttle-valve actuator, governor monitoring, bank 2 |- |'''Fault descripti...") (Tag: Visual edit) |
m (Rcollins moved page MSS60 Error: 2B16, P0639, P1630 to MSS60 Error: 2B16, P0639, P1630, P210A without leaving a redirect) |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | __FORCETOC__ | |
− | + | ||
− | | | + | |
+ | ==== '''2B16 - P1630''' ==== | ||
+ | {| class = "diyTable ecuFault" | ||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 56: | Line 58: | ||
− | + | ==== '''2B16 - P210A''' ==== | |
− | + | {| class = "diyTable ecuFault" | |
− | |||
− | {| | ||
− | |||
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 116: | Line 114: | ||
− | + | ==== '''2B16 - P0639''' ==== | |
− | + | {| class = "diyTable ecuFault" | |
− | |||
− | {| | ||
− | |||
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 176: | Line 170: | ||
− | + | ==== '''2B16 - P0639''' ==== | |
− | + | {| class = "diyTable ecuFault" | |
− | |||
− | {| | ||
− | |||
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' |
Latest revision as of 14:00, 3 February 2015
2B16 - P1630
Information saved in | DME |
Fault code | 2B16 - P1630 |
Fault text | Throttle-valve actuator, governor monitoring, bank 2 |
Fault description | Throttle Valve Circuit (Bank 2) |
Condition for fault identification | Test condition: Actuator shifts to Failsafe mode |
Terminal condition: TERM87 | |
Voltage condition: none | |
Condition for fault memory entry | 10 ms |
Action in service | 1. Clear fault memory, conduct EDR electronic throttle control system test, |
2. Check plug and wiring harness at DKG2 and EDR2, | |
3. Replace DKG2 or EDR Bank 2 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B16 - P210A
Information saved in | DME |
Fault code | 2B16 - P210A |
Fault text | Throttle-valve actuator, governor monitoring, bank 2 |
Fault description | Throttle Actuator 'B' Control Motor Circuit/Open |
Condition for fault identification | Test condition: Actuator shifts to Failsafe mode |
Terminal condition: TERM87 | |
Voltage condition: none | |
Condition for fault memory entry | 10 ms |
Action in service | 1. Clear fault memory, conduct EDR electronic throttle control system test, |
2. Check plug and wiring harness at DKG2 and EDR2, | |
3. Replace DKG2 or EDR Bank 2 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B16 - P0639
Information saved in | DME |
Fault code | 2B16 - P0639 |
Fault text | Throttle-valve actuator, governor monitoring, bank 2 |
Fault description | Throttle Actuator Control Range/Performance (Bank 2) |
Condition for fault identification | Test condition: Actuator reports system error |
Terminal condition: TERM87 | |
Voltage condition: none | |
Condition for fault memory entry | 10 ms |
Action in service | 1. Clear fault memory, conduct EDR electronic throttle control system test, |
2. Check plug and wiring harness at DKG2 and EDR2, | |
3. Replace DKG2 or EDR Bank 2 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B16 - P0639
Information saved in | DME |
Fault code | 2B16 - P0639 |
Fault text | Throttle-valve actuator, governor monitoring, bank 2 |
Fault description | Throttle Actuator Control Range/Performance (Bank 2) |
Condition for fault identification | Test condition: Actuator reports system error |
Terminal condition: TERM87 | |
Voltage condition: none | |
Condition for fault memory entry | 10 ms |
Action in service | 1. Clear fault memory, conduct EDR electronic throttle control system test, |
2. Check plug and wiring harness at DKG2 and EDR2, | |
3. Replace DKG2 or EDR Bank 2 | |
4. With UMWB engine protection check throttle valve assembly for stiction | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |