MSS60 Error: 2B0D, P152C, P152D, P152E, P152F

From Wiki-DIY
Revision as of 13:49, 3 February 2015 by Rcollins (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search


2B0D - P152C

Information saved in DME
Fault code 2B0D - P152C
Fault text Idle actuator monitoring, bank 1
Fault description Idle-Speed Control Valve Monitoring Dissimilar Desired Values (Bank 1)
Condition for fault identification Test condition: Difference too large
Terminal condition: TERM87
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min)
Condition for fault memory entry 300 ms
Action in service 1. Clear fault memory, LLS idle actuator system test
2. Check LLS1 voltage supply
3. Replace LLS1
Fault effect and breakdown warning DSC lamp / CC message / engine speed limited to 5000 rpm / reduced power / engine start may be possible only with use of accelerator pedal
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None


2B0D - P152D

Information saved in DME
Fault code 2B0D - P152D
Fault text Idle actuator monitoring, bank 1
Fault description Idle-Speed Control Valve Monitoring Incorrect Actual Value (Bank 1)
Condition for fault identification Test condition: Error detection received via CAN
Terminal condition: TERM87
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min)
Condition for fault memory entry 100 ms
Action in service 1. Clear fault memory, LLS idle actuator system test
2. Check LLS1 voltage supply
3. Replace LLS1
Fault effect and breakdown warning DSC lamp / CC message / engine speed limited to 5000 rpm / reduced power / engine start may be possible only with use of accelerator pedal
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None


2B0D - P152E

Information saved in DME
Fault code 2B0D - P152E
Fault text Idle actuator monitoring, bank 1
Fault description Idle-Speed Control Valve Monitoring Actual Value / Desired Value Correlation (Bank 1)
Condition for fault identification Test condition: Difference too large
Terminal condition: TERM87
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min)
Condition for fault memory entry 350 ms
Action in service 1. Clear fault memory, LLS idle actuator system test
2. Check LLS1 voltage supply
3. Replace LLS1
Fault effect and breakdown warning DSC lamp / CC message / engine speed limited to 5000 rpm / reduced power / engine start may be possible only with use of accelerator pedal
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None


2B0D - P152F

Information saved in DME
Fault code 2B0D - P152F
Fault text Idle actuator monitoring, bank 1
Fault description Idle-Speed Control Valve Monitoring Reset Error (Bank 1)
Condition for fault identification Test condition: Not identical for too long
Terminal condition: TERM87
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min)
Condition for fault memory entry 250 ms
Action in service 1. Clear fault memory, LLS idle actuator system test
2. Check LLS1 voltage supply
3. Replace LLS1
Fault effect and breakdown warning DSC lamp / CC message / engine speed limited to 5000 rpm / reduced power / engine start may be possible only with use of accelerator pedal
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None