Difference between revisions of "MSS60 Error: 27C5, P2430"

From Wiki-DIY
Jump to: navigation, search
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27C5 - P2430 |- |'''Fault text''' |Air-mass sensor, secondary air, plausibility |- |'''Fault description''' |S...")
 
 
Line 1: Line 1:
{|
+
__FORCETOC__
|
+
 
|
+
 
 +
==== '''27C5 - P2430''' ====
 +
{| class = "diyTable ecuFault"
 
|-
 
|-
 
|'''Information saved in'''
 
|'''Information saved in'''

Latest revision as of 13:37, 3 February 2015


Contents

27C5 - P2430

Information saved in DME
Fault code 27C5 - P2430
Fault text Air-mass sensor, secondary air, plausibility
Fault description Secondary Air Injection System Air Flow/Pressure Sensor Circuit (Bank 1)
Condition for fault identification Test condition: sls_obd_max after 10 sec. SLS operation under KL_SLS_OBD_HFM_DIAG_MIN or after 20 sec. SLS_operation sls_obdh_mdf_max_intg_norm < K_SLS_OBDH_EUV_MIN_DEF and higher exhaust gas lamda
Terminal condition: Engine running
Voltage condition: Battery voltage > 10.8 V (k_sls_obd_ub_min)
Condition for fault memory entry 30000 ms
Action in service 1. Remove secondary air line from secondary air pump
2. Conduct test routine
3. If secondary air pump runs/air flows out, and error is still logged, replace the mini-HFM
Fault effect and breakdown warning MIL is on after 2x engine cold start
Driver information Warning light: MIL
Service instruction None