Difference between revisions of "MSS60 Error: 27B8, P0692"

From Wiki-DIY
Jump to: navigation, search
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27B8 - P0692 |- |'''Fault text''' |Electric fan, activation |- |'''Fault description''' |Fan 1 Control Circuit...")
 
Line 1: Line 1:
{|
+
__FORCETOC__
|
+
 
|
+
 
 +
==== '''27B8 - P0692''' ====
 +
{| class = "diyTable ecuFault"
 
|-
 
|-
 
|'''Information saved in'''
 
|'''Information saved in'''

Revision as of 13:28, 3 February 2015


Contents

27B8 - P0692

Information saved in DME
Fault code 27B8 - P0692
Fault text Electric fan, activation
Fault description Fan 1 Control Circuit High
Condition for fault identification Test condition: ATIC39 diagnosis message
. Terminal condition: TERM87
. Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min)
Condition for fault memory entry 1000 ms
Action in service 1. Check plug and wire on ELUE
. 2. Check signal wire in wiring harness on DME
. 3. Replace ELUE
Fault effect and breakdown warning Fan has failed
. Constant rise in engine temperature leading to CC message
Driver information Warning light: none
Service instruction none