Difference between revisions of "MSS60 Error: 27AB, P0068, P0106, P2193"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27AB - P0106 |- |'''Fault text''' |Charge plausibility, diagnosis hot - bank 2 |- |'''Fault description''' |Ma...") (Tag: Visual edit) |
|||
Line 1: | Line 1: | ||
− | + | __FORCETOC__ | |
− | + | ||
− | | | + | ==== '''27AB - P0106''' ==== |
+ | {| class = "diyTable ecuFault" | ||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 44: | Line 45: | ||
− | + | ==== '''27AB - P0068''' ==== | |
− | + | {| class = "diyTable ecuFault" | |
− | {| | ||
− | |||
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 88: | Line 86: | ||
− | + | ==== '''27AB - P2193''' ==== | |
− | + | {| class = "diyTable ecuFault" | |
− | {| | ||
− | |||
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' |
Latest revision as of 13:21, 3 February 2015
Contents
27AB - P0106
Information saved in | DME |
Fault code | 27AB - P0106 |
Fault text | Charge plausibility, diagnosis hot - bank 2 |
Fault description | Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance |
Condition for fault identification | Test condition: Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to rpm/load factor) KF_FPLAU_OBD_PSAU_DELTA_ML_MAX * expansion factors (K_FPLAU_OBD_TE_F, KL_FPLAU_PSAU_PUMG_F) |
Terminal condition: Engine running | |
Voltage condition: none | |
Condition for fault memory entry | 10000 ms |
Action in service | 1. Check induction system B1 for leaks |
2. Replace intake manifold pressure sensor | |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | None |
27AB - P0068
Information saved in | DME |
Fault code | 27AB - P0068 |
Fault text | Charge plausibility, diagnosis hot - bank 2 |
Fault description | MAP/MAF - Throttle Position Correlation |
Condition for fault identification | Test condition: Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to rpm/load factor) KF_FPLAU_OBD_AQ_DELTA_ML_MAX * expansion factor (K_FPLAU_OBD_TE_F) |
Terminal condition: Engine running | |
Voltage condition: none | |
Condition for fault memory entry | 10000 ms |
Action in service | 1. Check induction system B1 for leaks |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | None |
27AB - P2193
Information saved in | DME |
Fault code | 27AB - P2193 |
Fault text | Charge plausibility, diagnosis hot - bank 2 |
Fault description | System Too Lean at Higher Load (Bank 2) |
Condition for fault identification | Test condition: Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to rpm/load factor) KF_FPLAU_OBD_AQ_DELTA_ML_MAX * expansion factor (K_FPLAU_OBD_TE_F) |
Terminal condition: Engine running | |
Voltage condition: none | |
Condition for fault memory entry | 10000 ms |
Action in service | 1. Check induction system B1 for leaks |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | None |