Difference between revisions of "MSS60 Error: 2742, P0135"

From Wiki-DIY
Jump to: navigation, search
(Created page with "{| |'''Information saved in''' |DME |- |'''Fault code''' |2742 - P0135 |- |'''Fault text''' |Oxygen sensor heater resistance diagnosis before cat. converter, bank 1 |- |'''Fau...")
 
 
Line 1: Line 1:
{|
+
__FORCETOC__
 +
 
 +
===='''2742 - P0135'''====
 +
{| class = "diyTable ecuFault"
 
|'''Information saved in'''
 
|'''Information saved in'''
 
|DME
 
|DME

Latest revision as of 20:34, 4 February 2015


Contents

2742 - P0135

Information saved in DME
Fault code 2742 - P0135
Fault text Oxygen sensor heater resistance diagnosis before cat. converter, bank 1
Fault description O2 Sensor Heater Circuit (Bank 1 Sensor 1)
Condition for fault identification Test condition: The upper or lower threshold of the resistance values has been violated, above/below 6.0 ohms (K_LSHVK_DIAG_RU) 14.5 ohms (K_LSHVK_DIAG_RO)
Terminal condition: Engine running
Voltage condition: Battery voltage > 9V (k_ed_ubmin)
Condition for fault memory entry min. K_LSHVK_DIAG_ANZ_MESS (100) valid calculations of heater resistance - roughly.1.5 sec.
Action in service 1. DME software release must be more recent than 07-06-510, fix incorporated since 07-09-521
2. Check plug, wiring harness on pre-cat oxygen sensor LSVK B1,
3. If OK, replace oxygen sensor
Fault effect and breakdown warning MIL lamp on after engine runs 2x /Small influence on drivability
Driver information Warning light: MIL
Service instruction None
MIL after engine runs 2x