Difference between revisions of "MSS60 Error: 272D, P0056, P0057, P0058"
From Wiki-DIY
(Created page with " {| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |272D - P0056 |- |'''Fault text''' |Oxygen sensor, output-stage diagnosis, heater behind cat., bank 2 |- |''...") (Tag: Visual edit) |
(No difference)
|
Revision as of 20:37, 11 January 2015
Information saved in | DME |
Fault code | 272D - P0056 |
Fault text | Oxygen sensor, output-stage diagnosis, heater behind cat., bank 2 |
Fault description | HO2S Heater Control Circuit (Bank 2 Sensor 2) |
Condition for fault identification | Test condition: Driver info includes OPENLOAD |
. | Terminal condition: none |
. | Voltage condition: none |
Condition for fault memory entry | 100 ms |
Action in service | 1. Check plug and wiring harness on post-cat sensor LSNK B2, |
. | 2. If OK replace sensor |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | none |
Information saved in | DME |
Fault code | 272D - P0057 |
Fault text | Oxygen sensor, output-stage diagnosis, heater behind cat., bank 2 |
Fault description | HO2S Heater Control Circuit Low (Bank 2 Sensor 2) |
Condition for fault identification | Test condition: Driver info includes short circuit to ground |
Terminal condition: none | |
Voltage condition: None | |
Condition for fault memory entry | 100 ms |
Action in service | 1. Check plug and wiring harness on post-cat sensor LSNK B2, |
2. If OK replace sensor | |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | None |
Information saved in | DME |
Fault code | 272D - P0058 |
Fault text | Oxygen sensor, output-stage diagnosis, heater behind cat., bank 2 |
Fault description | HO2S Heater Control Circuit High (Bank 2 Sensor 2) |
Condition for fault identification | Test condition: Driver info includes short circuit to battery voltage |
Terminal condition: none | |
Voltage condition: None | |
Condition for fault memory entry | 100 ms |
Action in service | 1. Check plug and wiring harness on post-cat sensor LSNK B2, |
2. If OK replace sensor | |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | None |